DL-150

EVERLAST METALS: DL-150
Metal Roofing Panel Profile


Everlast Metals DL-150 Double-Lock Standing Seam roofing panel utilizes the proven seaming process of Mechanical Locking in conjunction with the floating action of a concealed clip assembly. This design allows for expansion & contraction caused by natural elements, providing a virtually leak proof roof with exceptional wind uplift ratings.

The panel is available in a wide variety of materials and finishes. Substrates include G-90 Galvanized Steel, Galvalume® steel, and Aluminum. All painted products are Fluropon® coated.

An optional thermally applied pre-assembly in-seam sealant is available. The minimum slope requirement is 1.5:12.


METHOD OF APPLICATION:

Everlast Metals DL-150 panels must be installed in a sequential pattern. Application of an Everlast Metals approved underlayment prior to panel installation is recommended when installed over a solid substrate. Panels must be locked in the field by a mechanical seamer.


Storage:

Everlast Metals metal panels should be stored in a well-ventilated, dry place where no moisture can contact them. Moisture (from rain, snow, condensation, etc.) trapped between layers of material may cause water stains or white rust, which can affect the service life of the material and will detract from its appearance. If outdoor storage cannot be avoided, protect the panels with a ventilated canvas or waterproof paper cover. Do not use plastic, which can cause condensation. Keep the material off the ground in an inclined position with an insulator such as wood. Protective film may degrade or become brittle with long-term exposure to direct sunlight.


Panel Size:

Panel Widths: 12", 16", 20"
Seam Height: 1.5"
Min. Panel Length: 4’
Max. Panel Length: 40’ (Longer lengths require on-site rollforming)


Testing:

ASTM E 1592 Structural

ASTM E 1680 Air Penetration Roofs

ASTM E 1646 Water Infiltration Roofs

TAS125(UL90) Florida Product Approval

TAS100 Wind Driven Rain

TAS201 Impact Resistance

Class 4 Hail Resistance

ASTM E 330 Structural

ASTM E 283 Air Leakage

ASTM E 331 Water Penetration

ASTM E 72 Structural


Projects


Segment: Government
Project: Maryland National Parks & Planning
Location: Fort Washington, MD
Quantity: 260 sq

Segment: Municipal
Project: Salt Storage Facility
Location: Fort Kent, ME
Quantity: 88 sq

Segment: Government
Project: Massebesic Forest Administration Building
Location: Lyman, ME
Quantity: 40 sq

Segment: Municipal
Project: Salt Storage Facility
Location: Bethel, ME
Quantity: 70 sq