The Everlast Metals ASL-100 Architectural Snap Seam Standing Seam roofing panel utilizes snap together panels for quick installation and no field seaming required.
Installed over solid decking, this design allows for expansion & contraction caused by natural elements, providing a virtually leak proof roof with exceptional UL580 wind uplift ratings.
The panel is available in a wide variety of materials and finishes. Substrates include G-90 Galvanized Steel, Galvalume® steel, and Aluminum. All painted products are Fluropon® coated.
Everlast Metals ASL-100 panels must be installed in a sequential pattern. Application of an Everlast Metals approved underlayment prior to panel installation is recommended when installed over a solid substrate.
Everlast Metals metal panels should be stored in a well-ventilated, dry place where no moisture can contact them. Moisture (from rain, snow, condensation, etc.) trapped between layers of material may cause water stains or white rust, which can affect the service life of the material and will detract from its appearance. If outdoor storage cannot be avoided, protect the panels with a ventilated canvas or waterproof paper cover. Do not use plastic, which can cause condensation. Keep the material off the ground in an inclined position with an insulator such as wood. Protective film may degrade or become brittle with long-term exposure to direct sunlight
Panel Widths: 13", 17", 21"
Seam Height: 1"
Min. Panel Length: 4’
Max. Panel Length: 40’ (Longer lengths require on-site rollforming)
Class 4 Hail Resistance
TAS125(UL90) Florida Product Approval
TAS100 Wind-Driven Rain